Rebar calculator
Enter the slab size and bar spacing. You get bars in each direction, total linear feet, the number of stock lengths to buy, and the weight of steel.
Slabs on grade usually take #4 at 12 in on centre each way. ACI 318 caps spacing at 3 × slab thickness or 18 in, whichever is smaller. The 20 in lap is 40 bar diameters — the usual rule for #4 in tension.
Affiliate link. The cost above is a bill of materials at the prices you entered — it is not a quote, and it excludes labour and delivery.
A 24 × 24 ft slab with #4 bar at 12 in on centre each way needs 25 bars in each direction. With a 20 in lap at every splice and 10% waste, that is 1,283 linear feet of steel — 71 twenty-foot sticks, or about 857 lb.
What the calculator assumes
- A rectangular slab with a two-way grid. Bars run parallel to both axes, spaced evenly, with one bar at each edge. That is why the count is
slab width ÷ spacing + 1rather thanslab width ÷ spacing. - 20 ft stock lengths, which is what a building supply actually sells. If your yard stocks 30 ft or 40 ft bar, change the field — the stick count drops sharply.
- A 20 in lap at every splice. Forty bar diameters is the standard rule of thumb for #4 in tension. Shortening the lap to 12 in saves a few sticks and is the most common way a slab ends up under-reinforced at the joints.
- 10% waste, which covers cut-offs, bent bars and the piece you drop in the trench. Bar cannot be spliced back together, so this allowance is not padding.
- Weight is computed from the nominal bar weight, not from the purchased stick count, so it reflects the steel in the slab rather than the offcuts in your truck bed.
Bar sizes and weights
| Bar | Diameter | Weight | 20 ft stick | Typical use |
|---|---|---|---|---|
| #3 | 3/8 in | 0.376 lb/ft | 7.5 lb | Mesh replacement, patios, curbs |
| #4 | 1/2 in | 0.668 lb/ft | 13.4 lb | Driveways, slabs, footings |
| #5 | 5/8 in | 1.043 lb/ft | 20.9 lb | Structural slabs, retaining walls |
| #6 | 3/4 in | 1.502 lb/ft | 30.0 lb | Heavy foundations, columns |
Grade matters for strength, not for weight. A stick of grade 40 and a stick of grade 60 #4 weigh the same 13.4 lb; what changes is the yield stress, and therefore how much load that bar can carry before it stretches.
Spacing by application
| Application | Spacing | Bar |
|---|---|---|
| Driveway slab | 12 in each way | #4 |
| Garage slab | 12–18 in each way | #4 |
| Patio, shed base | 18 in each way | #3 or #4 |
| Strip footing | 3–4 continuous bars | #4 or #5 |
| Block wall | 24 in vertical, 24–48 in horizontal | #4 |
| Column (sonotube) | 4 vertical bars | #4 or #5 |
The 18 in ceiling in ACI 318 is not a suggestion. Spacing wider than that leaves the concrete between bars free to crack and curl, and on a slab on grade that shows up as a crack pattern within the first winter.
Why the stick count is higher than the bar count
A 24 × 24 ft slab is 50 bars. It is also 71 sticks. That gap surprises people, and it is not an error.
Each 24 ft run cannot be cut from one 20 ft bar. It needs two, joined with a lap — and the lap itself consumes 20 in of the second bar, so the second bar contributes only 18 ft 4 in of new length. Short runs waste a lot; long runs waste less per foot. This is why a 40 ft bar, where it is available, is almost always cheaper per linear foot than two 20 ft bars.
The calculator lets offcuts be reused between runs, which is what a competent crew does. It does not assume the fabricator pre-bends everything perfectly, which is why the waste allowance exists.
The counting rule — run ÷ spacing + 1, then converted to stock lengths — is written out with the rest of the constants on the method page.
Where the number goes wrong
Bars laid on the ground. Rebar only works in tension if the concrete surrounds it. On a slab on grade, bars need to sit roughly a third of the way up the slab — 1.5 in of cover below, 2 in below the surface on a 4 in slab. That requires chairs or dobies, and they are never in the rebar quote.
Forgetting the thickened edge. A driveway apron or slab with a turned-down edge needs additional bar in the footing portion, and the slab grid does not cover it.
Splicing all bars at the same point. Laps should be staggered so that no cross-section of the slab is more than half spliced. The calculator counts laps but cannot stagger them for you.
Ordering from the linear-foot total. Bar is sold in stock lengths, not by the foot. Always order the stick count, and check whether the yard charges for cutting.
Rebar questions
How many sticks of #4 rebar for a 24 × 24 slab?
Seventy-one 20 ft sticks at 12 in on centre, allowing a 20 in lap at each splice and 10% waste. That is 50 bars in total — 25 running each way — but each 24 ft run needs two sticks, which is what pushes the count up.
What size rebar should a 4 inch slab use?
Number 4 (1/2 in) at 12 to 18 in on centre is the usual spec for a driveway or garage slab. A garden path or shed base often uses #3 or welded wire mesh instead. The engineered drawing governs, and it is the only thing an inspector will read.
How much does #4 rebar weigh per foot?
0.668 lb per foot, so a 20 ft stick is 13.4 lb. Number 3 is 0.376 lb/ft, #5 is 1.043 lb/ft and #6 is 1.502 lb/ft. These are ASTM nominal weights and they do not change with grade — grade 40 and grade 60 weigh the same.
How far apart should rebar be in a slab?
ACI 318 caps spacing at the lesser of three times the slab thickness or 18 in. A 4 in slab therefore cannot exceed 12 in between bars, which is why 12 in on centre is the default here.
How long should a rebar lap be?
Forty bar diameters is the common rule: 20 in for #4, 25 in for #5. Structural drawings usually specify a class A or class B tension lap, which is calculated rather than tabulated. When in doubt, lap longer — a lap that is too short is the one defect you cannot inspect after the pour.
Do I need rebar or wire mesh?
Mesh holds a slab together against shrinkage cracking and is fine for patios and shed floors. Rebar carries load, so it belongs in driveways, garage slabs and anything over about 5 in thick. Mesh is also often laid on the ground rather than chaired up, which makes it nearly useless.